Written from the drawing.
Instrument indexes, I/O lists, loop checks, revision control and the standards behind them, written for the engineer holding the P&ID.
Older articles.
Page 7 of 10
- Redundant I/O. How 1oo2, 2oo3, and 2oo4 Voting Show Up on the I/O ListHow to represent voted sensor sets and redundant final elements on the SIS I/O list. One row per physical device, suffixed tags, shared SIF identifier.
- IEC 61511 for the I&C Engineer Building the SIS I/O ListThe working subset of IEC 61511 an I&C engineer needs, from reading the LOPA output through documenting proof-test intervals on the SIS I/O list.
- I/O List to Wiring. Termination and MarshallingThe I/O list says which channel. The termination schedule says which wire. This walks the chain from field instrument to PLC card terminal.
- Soft Tags vs Hard I/O. What Belongs on the I/O ListA hard I/O point is a wire on a card. A soft tag is a value the controller computes or reads over a bus. Only hard channels belong on the I/O list.
- Building an I/O List From P&IDsBuilding an I/O list from P&IDs: extract, classify, dedup, assign, and freeze the list, with worked examples and what stays off it.
- Spare I/O Percentage. How Much to CarryA flat 20% spare wastes budget on DO and under-provisions AI. The number that matters is the one you compute per type, against the client spec.
- What Is Not an Instrument. Tags That Don't Belong on the I/O ListAn I/O list counts wired field signals, not every tagged item on a P&ID. Hand valves, local gauges, and legend entries carry tags but earn no channel.
- Brownfield I/O Reconciliation. Keep, Remove, ReplaceOn a revamp the drawings, the field, and the control system rarely agree. Reconciliation is the pass that makes the I/O list defensible.
- AI, AO, DI, DO Signal Classes ExplainedAI analog input, AO analog output, DI digital input, DO digital output. The full form of each, typical devices, and an I/O list template to fill.
- The Line List Explained. Contents and SourcesThe line list is the master register of every process line on the P&IDs, distinct from the I/O list and index, and the input to stress, MTO, and isometrics.
- PLC Tag Naming Conventions. P&ID to DCSThe P&ID tag, the PLC variable name, and the asset-management ID are related but not the same string. The naming convention is what keeps them in sync.
- PLCCreator Device I/O List Format ExplainedWhat PLCCreator's IO list templates contain. The Signal IO List and Device IO List, the marker row, the headers per architecture and the Signal Type list.
We run it on your drawings.
Your P&ID set comes back as the instrument index, the I/O list and the equipment, line and valve registers.