Two revisions, every change.
Two P&ID revisions in, one change list out: added, removed and changed instruments. Export the Change Report for the MOC package.
Sheet to sheet.
Each instrument matched across the two revisions. New tags surface on the right, dropped tags on the left, every changed field highlighted in place.
What the Change Report carries.
- Three categories per comparison. Added, removed, modified. Full instrument row attached to every entry: tag number, instrument type, signal class, description, equipment owner, source-page reference.
- Field-level diff on modified instruments. Signal class, fail position, description, range, equipment link. Each line item shows the value before and the value after so the reviewer sees exactly what moved.
- Excel workbook ready for MOC attachment. One sheet per category, formatted with column widths, auto-filter, freeze pane. Drops directly into the Management of Change document without reformatting.
- Comparison history per facility. Every saved diff is retrievable from the facility detail page, with MOC notes and a timeline view. Old comparisons can be re-opened, their diff viewed again, and the Excel re-downloaded.
From two revisions to an MOC attachment.
Each revision comes back as its own project, and the comparison lists the instruments added, removed or changed.
- The Change Report is an Excel workbook that attaches to the Management of Change document as it is.
- Each saved comparison stays on the facility timeline with its MOC notes, ready to reopen for the audit.
Common questions
How does Tagsight compare two P&ID revisions?
Each revision is held as its own project, and the Revision Comparison shows which instruments were added, removed or changed between them.
Can I export the diff for an MOC package?
Yes. The Change Report export is an Excel workbook with three sheets ready to attach to a Management of Change document. Save the comparison with MOC notes for the facility audit trail.
What counts as a modification?
Any change to an instrument present in both revisions: signal class flipping from AI to AO, fail position changing, description being updated, equipment reassignment, range change. Each modification is shown field by field so the reviewer sees exactly what moved.
Do the drawings have to be in the same format?
No. A scanned revision A can be compared against a CAD-exported revision B. The difference in drawing format does not block the comparison.
Is the comparison history saved?
Yes. Every saved comparison is stored against the facility and shown on a timeline. Old comparisons can be re-opened, their diff viewed, and the Change Report downloaded again.
How is a comparison scoped?
As part of the pilot, in its written order, with the drawings it covers.