Puntlijsten, read straight from the regeltechniek set.
NEN-tagged air-handling and climate-control drawings, read into a puntlijst with the I/O class on every point. The tag codes ISA-only tools reject, kept exactly as the drawing prints them and ready for your controls platform.
Your tag codes come through unchanged.
An ISA-only reader rejects a NEN code or forces it into a five-character ISA shape. Tagsight keeps the code exactly as the drawing prints it and adds the I/O class beside it, so the puntlijst still matches the panel and the sheet.
How a puntlijst runs through Tagsight.
- 01Upload the regeltechniek set.Drag the air-handling and climate-control drawings, installation schematics, and existing point lists into a workspace. PDF, scanned, or image. Vector PDFs read fastest; scans are read at high resolution and uncertain points you review before export.
- 02Review the points.Each point appears on the review canvas with its bubble shown on the source drawing. The original NEN tag is kept; the I/O class is shown for you to confirm or correct. Every edit is logged against the point it changed.
- 03Export the puntlijst.Export the puntlijst as Excel or CSV, or as a TIA Portal XML or Studio 5000 L5X tag table when the controller is known. The controls team imports the file directly on their workstation.
Upload the regeltechniek set.
Drag the air-handling and climate-control drawings, installation schematics, and existing point lists into a workspace. PDF, scanned, or image. Vector PDFs read fastest; scans are read at high resolution and uncertain points you review before export.
Each point appears on the review canvas with its bubble shown on the source drawing. The original NEN tag is kept; the I/O class is shown for you to confirm or correct. Every edit is logged against the point it changed.
Export the puntlijst.
Export the puntlijst as Excel or CSV, or as a TIA Portal XML or Studio 5000 L5X tag table when the controller is known. The controls team imports the file directly on their workstation.
Op de puntlijst.
| Tag | I/O | Omschrijving |
|---|---|---|
| AB2-VB-04 | DI | Vorstbeveiliging |
| AB2-WV-05 | AO | Verwarmingsklep |
| AB2-VR-06 | DI | Ventilator bedrijf |
Veelgestelde vragen
What is a puntlijst and how does it differ from an I/O list?
Does Tagsight read NEN-tagged drawings, not just ISA 5.1?
What climate-installation documents can I upload?
Which tag codes and descriptions come out on the puntlijst?
Can I export the puntlijst to a controls platform?
How is a revision handled when the installation changes?
Puntlijsten, read straight from the regeltechniek set.
NEN-tagged air-handling and climate-control drawings, read into a puntlijst with the I/O class on every point. The tag codes ISA-only tools reject, kept exactly as the drawing prints them and ready for your controls platform.