Header row
Formatted, frozen, with set column widths so the sheet scrolls cleanly on long registers.
A motor control center, MCC schedule is the bucket-by-bucket register of every motor controlled from a given MCC section. One row per bucket carries the motor tag, driven equipment, rated horsepower, voltage, full load amps, starter type, FVNR, FVR, RVAT, VFD, soft-start, starter class, breaker rating, overload setting, control method, local, remote, DCS, PLC, HOA, and lockout point reference.
MCC schedule template with 12 columns covering bucket position, motor tag, driven equipment, HP, voltage, FLA, starter type, starter class, breaker rating, overload setting, control method, and lockout reference. Pre-formatted with frozen header, auto-filter, and 48 blank rows.
12 columns mapped to how a motor control center schedule is issued on a real project. Dropdown columns enforce values; free-text columns let house notation preserve as drawn.
| # | Column | Type | Description |
|---|---|---|---|
| 01 | Bucket Position | Text | MCC section and bucket reference |
| 02 | Motor Tag | Text | Driven motor tag |
| 03 | Driven Equipment | Text | Driven equipment tag |
| 04 | HP, kW | Text | Motor power rating |
| 05 | Voltage | Text | Rated voltage |
| 06 | FLA | Text | Full load amps |
| 07 | Starter Type | List | FVNR, FVR, RVAT, VFD, Soft-start |
| 08 | Starter Class | Text | NEMA size or IEC class |
| 09 | Breaker Rating | Text | Breaker amperage |
| 10 | Overload Setting | Text | Overload amperage setpoint |
| 11 | Control Method | List | Local, Remote, DCS, PLC, HOA |
| 12 | Lockout Reference | Text | Lockout point location reference |
Formatted, frozen, with set column widths so the sheet scrolls cleanly on long registers.
One filled row shows the format for every column so the schema is clear before the engineer starts typing.
Enabled on every column. Pivot by any field without a single formula.
Pre-formatted and ready to paste into. Extends without breaking the dropdown or filter range.
Categorical columns (priority, signal class, status, type) enforce values so the register stays clean.
Plain .xlsx. Opens cleanly in Excel, Google Sheets, and LibreOffice. No macros, no add-ins.
No macros, no add-ins, no telemetry inside the file. Edit and ship.
A single mint-italic line at the bottom: Drag a source document at tagsight.io to fill this automatically. Easy to delete.
Upload the source document instead and the same 12-column schema this template defines comes back populated. Type, tag, vendor, model, and per-row metadata come from the document itself.
Scanned binders, CAD-exported PDFs, and image scans all work. House conventions, vendor-specific forms, and dialect-specific tag schemes read as drawn.
The template is a manual starting point you fill yourself. Upload the source document instead and the same schema comes back populated.