Lighting schedule to Excel.
An electrical lighting schedule is the building services register of every lighting fixture on a project. One row per fixture tag carries the room or space served, quantity, manufacturer, model number, lamp type (LED, fluorescent, HID, sodium), lumen output, color temperature in Kelvin, mounting height, voltage, circuit assignment, and control method (manual, 0-10V dimming, DALI, DMX, occupancy sensor). The egress and emergency subset filters out for the life-safety inspection package.
Upload an electrical lighting schedule, a fixture submittal, or a legacy room-by-room register and extract every fixture into a structured spreadsheet. Fixture tag, room, quantity, manufacturer, model, lamp type, lumen output, voltage, circuit, and control method all read into the columns the lighting designer and the commissioning electrician use.
| Audience | Uses for | Filter applied |
|---|---|---|
| Electrical contractor | Per-room takeoff for ordering | Grouped by manufacturer + model |
| Lighting designer | Verify lumens against task lighting design | Lumens + color temperature |
| BAS controls integrator | DDC point list per dimming controller | DALI + 0-10V subset |
| Life-safety inspector | Egress fixture verification | Emergency + dual-circuit subset |
| Energy auditor | ASHRAE 90.1 lighting power density (LPD) | Per-zone wattage sum |
Fields extracted.
Every column the electrical lighting schedule typically carries is read and shaped into a structured row. Missing fields stay blank, never invented.
- Fixture tag
- Room / Space
- Quantity
- Manufacturer
- Model / Part No.
- Lamp typeLED, fluorescent, HID, sodium
- Lumen output
- Color temperatureKelvin
- Mounting height
- Voltage
- Circuit
- Control methodmanual / 0-10V / DALI / DMX / occupancy
- Emergency / Egressyes / no / dual-circuit
- Notes
Export targets.
The extracted data ships in the format your team picks up and uses directly.
- .xlsxExcel workbook (lighting schedule)
- .csvCSV
- .xlsxPer-room fixture takeoff for ordering
From legacy file to clean register.
Common questions.
Does this handle DALI and DMX controlled lighting?
Yes. The control method column distinguishes manual, 0-10V dimming, DALI, DMX, and occupancy-sensor controls. DALI device addressing (a runtime commissioning step in the lighting controller) is not part of the design-drawing extraction; the field is reserved for the commissioning step to fill.
Can the per-room fixture takeoff feed an electrical estimator's bid?
Yes. The takeoff export carries quantity per room per fixture type with the model number; the bid sheet groups by manufacturer and model so the wholesaler can quote against a clean line-item count.
What about emergency and egress fixtures?
The Emergency / Egress column distinguishes egress fixtures, dual-circuit emergency fixtures, and dedicated emergency packs. The egress subset filters into a separate sheet for the life-safety inspection package.
Convert your file.
Upload a electrical lighting schedule in any format, get every row read, every column shaped, every reference preserved, then export the workbook your team uses next.